[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Cochlea Amplifier models : a new list
At 6:28 PM +0200 10/10/07, Martin Braun wrote:
Can you specifically give a reference for studies that show neural 
tuning at high sound levels which have in some way controlled for 
response saturation?
Response saturation is not an issue here. You can determine the CFs 
of a neuron at 60 dB and at 90 dB. A half-octave shift of CF, say 
from 1 kHz to 1.4 kHz, has to my knowledge never been recorded.
CF usually means the frequency of greatest sensitivity, that is, the 
frequency corresponding to the lowest intensity that causes some 
criterion output level.  What do you mean here by "CFs of a neuron at 
60 dB and at 90 dB"?  Where can we see such data?
Dick