Re: spectrum level to RMS (Chas Pavlovic )


Subject: Re: spectrum level to RMS
From:    Chas Pavlovic  <pavlovic@xxxxxxxx>
Date:    Mon, 20 Jun 2011 14:12:10 -0700
List-Archive:<http://lists.mcgill.ca/scripts/wa.exe?LIST=AUDITORY>

Merri, Assuming a uniform spectrum level within the band the noise is measured: Spectrum Level = Band Level - 10 log(noise bandwidth in Hz). Incidentally, both of these are RMS values - the differentiation is that one of these RMSs is a "band level" and the other "spectrum density level". Also, these should be in the same units (both SPL, both db A, etc). Similarly, the RMS values should be obtained using the same averaging time (presumably "long" in your application). chas On 6/20/2011 10:01 AM, Merri J. Rosen wrote: > Hello all, > > I'm looking for a particular formula related to calibration. Noise amplitudes are often reported in spectrum level (aka equivalent SPL), i.e., the sound intensity in a 1kHz band, often reported as dB/Hz. I am calibrating my noise by directly measuring its RMS (in pascals), and calculating dB SPL from there. I would like a formula that converts spectrum level (dB/Hz) to RMS (assuming you know the bandwidth of the noise), in order to be able to relate spectrum level to my calculated dB SPL. Any suggestions are appreciated. > > thanks, > Merri > > > -------------------------------------------------------------------- > Merri J. Rosen, Ph.D. > Assistant Professor, Department of Anatomy& Neurobiology > NEOMED (Northeast Ohio Medical University) > mrosen@xxxxxxxx > http://www.neoucom.edu/audience/about/departments/anatneuro/faculty/rosen > Office: 330/325-6516 Lab: 330/325-6633 > -------------------------------------------------------------------- > > > > > > > ________________________________ > All branding for NEOUCOM will officially change to Northeast Ohio Medical University effective Aug. 15, 2011. Please note the impending change in our website address to www.neomed.edu and email to @xxxxxxxx >


This message came from the mail archive
/var/www/postings/2011/
maintained by:
DAn Ellis <dpwe@ee.columbia.edu>
Electrical Engineering Dept., Columbia University