I am working on speech quality assessment. When reading the source code of ITU-T P.862, I noticed that in the function "time_avg_audible_of" the pitch power density above 100 times the absolute hearing threshold is sumed. But in the section 10.2.6 of ITU-T P.862 "Perceptual evaluation of speech quality (PESQ):An objective method for end-to-end speech quality assessment of narrow-band telephone networks and speech codecs ", it says "power is more than 1000 times the absolute hearing threshold". I wonder if there is something wrong with the source code or the recommendation. Also, in the function of "pesq_psychoacoustic_model", the code of "frame_disturbance [frame] /= h;" may be "frame_disturbance [frame] *= h" acording to the section of 10.2.11 in the recommendation. Could anyone help me out with this?