Re: AUDITORY Digest - 28 Nov 2001 to 29 Nov 2001 (#2001-211) (Jason Summers )


Subject: Re: AUDITORY Digest - 28 Nov 2001 to 29 Nov 2001 (#2001-211)
From:    Jason Summers  <summej2(at)rpi.edu>
Date:    Fri, 30 Nov 2001 21:14:58 -0500

> > Dear List, > > We are conducting research on auditory model based front-ends for > automatic speech recognition in reverberant acoustic conditions. ... > Thanks in advance! > Regards, > Kalle Palomaki > --- Kalle, I'm not so sure about the signal to noise ratio of the impulses which you found on the web. For convolution with signals we like to have S/N >= 60dB at mid-frequencies. These we will be fairly difficult to find. Yamaha has produced a set of IR's for use with their new convolver that are quite nice but I don't believe that they are available any other way than purchasing the unit. I may personally have some of the IR's you would need from some of my own work. What sort of source to receiver distances are you looking for? All of the possible IR's would have source to receiver distances that are quite large (performer to audience or lecturer to student for example). Jason Summers Rensselaer Polytechnic Institute > > Subject: Measuring Reverberation time > > I am looking for references for appropriate techniques for measuring = > reverberation time of a medium sized room (approx. 40'x40'x20'). In = > specific, number and position of loudspeakers, level and type of signal. = > Does your technique and stimuli vary depending on your question of = > interest (e.g. absorption characteristics versus effects on sound = > quality or speech intelligibility)? We are interested in speech = > intelligibility by the way. I have ordered an IEC standard that = > supposedly describes a "standard" method for measuring reverb times when = > examining the absorption characteristics of materials. Any thoughts are = > appreciated. > > Thanks, > > Ben Hornsby Ben, These days most of us investigating room acoustics measure the impulse response of a room and derive measures like RT from the impulse response. Measuring the IR correctly will require some specialized equipment however: omnidirectional loudspeaker, etc. while it would be possible to get an approximation of RT much more simply. It is a question of desired precision and accuracy. ISO 3382 is the best standard I know of for measurement of both reverberation time and impulse response. However, the latest edition of Kuttruff's Room Acoustics will have much of the information in the ISO standard and far more background information. The number of measurement positions will depend both on the size of the room since RT varies statistically through a space. Both Kuttruff's book and the ISO standard detail this. Jason Summers Rensselaer Polytechnic Institute


This message came from the mail archive
http://www.auditory.org/postings/2001/
maintained by:
DAn Ellis <dpwe@ee.columbia.edu>
Electrical Engineering Dept., Columbia University