Re: Simultaneous Auditory Masking (William Treurniet )


Subject: Re: Simultaneous Auditory Masking
From:    William Treurniet  <bill.treurniet(at)CRC.CA>
Date:    Tue, 21 Mar 2000 10:43:56 -0500

Although it may be more than what you are looking for, there is a recent publication in the JAES describing an auditory model for measuring the perceived quality of wide band audio. The method is recommended by the International Telecommunications Union (ITU) for this purpose. The reference is Thiede T., Treurniet W., Bitto R., Schmidmer C., Sporer T., Beerends J., Colomes C., Keyhl M., Stoll G., Brandenburg K., and Feiten, B. (1999). PEAQ - the ITU standard for objective measurement of perceived audio quality, J. Audio Eng. Soc. 48, 3-29, 2000 (Jan/Feb). Additional details of the model may be found in the ITU Recommendation 1387, "Method for objective measurement of perceived audio quality". ----- Original Message ----- From: flatmax <flatmax(at)CSE.UNSW.EDU.AU> To: <AUDITORY(at)LISTS.MCGILL.CA> Sent: Tuesday, March 21, 2000 12:49 AM Subject: Simultaneous Auditory Masking > Hello, > > I was wondering wether anyone has implemented the masking methods > specified in : > "A Model for the Prediction of Thresholds, Loudness, and Partial > Loudness", Moore B.C.J., Glasberg B.R. and Baer T., > Journal of the Audio Engineering Society, > vol. 45, no. 4, April 1997, pp.224-40. > > Also has anyone implemented any other methods of masking ? > > thanks > Matt >


This message came from the mail archive
http://www.auditory.org/postings/2000/
maintained by:
DAn Ellis <dpwe@ee.columbia.edu>
Electrical Engineering Dept., Columbia University