[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: dB SPL to dBA
On dB SPL to dBA
Here are the numbers for A, C and D-filter
Freq A C D
10 -14.3 -26.6
12.5 -63.4 -11.2 -24.6
16 -56.7 -8.5 -22.6
20 -50.5 -6.2 -20.6
25 -44.7 -4.4 -18.7
31.5 -39.4 -3 -16.7
40 -34.6 -2 -14.7
50 -30.2 -1.3 -12.8
63 -26.2 -0.8 -10.9
80 -22.5 -0.5 -9
100 -19.1 0.3 -7.2
125 -16.1 -0.2 -5.5
160 -13.4 -0.1 -4
200 -10.9 0 -2.6
250 -8.6 0 -1.6
315 -6 0 -0.8
400 -4.8 0 -0.4
500 -3.2 0 -0.3
630 -1.9 0 -0.5
800 -0.8 0 -0.6
1000 0 0 0
1250 0.6 0 2
1600 1 -0.1 4.9
2000 1.2 -0.2 7.9
2500 1.3 -0.3 10.4
3150 1.2 -0.5 11.6
4000 1 -0.8 11.1
5000 0.5 -1.3 9.6
6300 -0.1 -2 7.6
8000 -1.1 -3 5.5
10000 -2.5 -4.4 3.4
12500 -4.3 -6.2 1.4
16000 -6.6 -8.5 -0.7
20000 -9.3 -11.2 -2.7
freq. A C D
Torben Poulsen, Department of Acoustic Technology
Building 352, Technical University of Denmark
DK-2800 Lyngby, Denmark
Voice: +45 4525 3940 (direct); +45 4588 1622 (Departm.)
Fax: +45 4588 0577
E-mail: tp@dat.dtu.dk http://www.dat.dtu.dk/